Contact our expert team today!


NORTHERN CALIFORNIA BRANCH
468 Yolanda Ave. Suite 201
Santa Rosa, CA 95404
707-575-9117


SOUTHERN CALIFORNIA BRANCH
9087 Arrow Route #130
Rancho Cucamonga, CA 91730
909-476-0085


TEXAS BRANCH
712 N. General Bruce Dr.
Temple, TX 76504
254-481-0087

Notes

Orders placed on the weekend will be processed the next following business day.

Also, express orders placed past 2pm may not be processed the same day PST.


Popular Links

About Fire Safety Supply

Since 1999, Fire Safety Supply has been the go-to for fire suppression products, industrial dry chemical systems, high and low-pressure CO2, vehicles, and clean agents. We serve various types of industries such as restaurants, commercial kitchen, wineries, and more.

Our expert team is factory-trained across all our product lines. Do you have a technical question about a special hazard system? Our knowledgeable staff is just a call away! With extensive industry resources, we are here to help you tackle any fire suppression challenge.

Skip to main content

ANSUL Cleanguard+ Fire Extinguishers

Compare ANSUL CLEANGUARD+ Clean-agent extinguisher models, part numbers, FK-5-1-12 capacities, discharge performance, effective range, approvals, marine classifications, dimensions, charged weight, fire-suppression capabilities, and compatible brackets. For assistance selecting the proper extinguisher, call Fire Safety Supply at 1-800-498-3473.

Browse by CLEANGUARD+ Model
No matching CLEANGUARD+ extinguisher models were found.

CA03VB

Domestic Part No. 443475
International Part No.443577
Bracket Part No.24610
AgentFK-5-1-12
Agent Capacity3.5 lb (1.59kg)
Charged Weight6.08 lb (2.76kg)
Discharge Time8.9 sec
Agent Flow Rate0.46 lb/sec (0.21kg/sec)
Listings and ApprovalsUL/ULC
USCG Classification
Effective Range8 ft - 10 ft (2.4m-3.1m)
Dimensions: Height × Width × Depth14-1/4 in (362mm)
5-3/4 in (146mm)
3-3/8" (86mm)
Fire Suppression Capability: UL Panel Class A / Novice Operator Class B / Experienced Operator Class BN/A
2ft² (0.19m²)
5ft² (0.47m²)

CA07

Domestic Part No. 443476
International Part No.443578
Bracket Part No.429146
AgentFK-5-1-12
Agent Capacity7.5 lb (3.46kg)
Charged Weight12.12 lb (5.5kg)
Discharge Time8.2 sec
Agent Flow Rate1.12 lb/sec (0.1kg/sec)
Listings and ApprovalsUL/ULC/USCG
USCG ClassificationType B:C, Size I
Effective Range8 ft - 10 ft (2.4m-3.1m)
Dimensions: Height × Width × Depth16-3/4 in (425mm)
8-1/2 in (216 mm)
4-7/16 in (113mm)
Fire Suppression Capability: UL Panel Class A / Novice Operator Class B / Experienced Operator Class BN/A
5ft² (0.47m²)
12.5ft² (1.2m²)

CA13

Domestic Part No. 443477
International Part No.443579
Bracket Part No.435793
AgentFK-5-1-12
Agent Capacity13.0 lb (5.9kg)
Charged Weight20.08 lb (9.11kg)
Discharge Time10.7 sec
Agent Flow Rate1.43 lb/sec (0.65kg/sec)
Listings and ApprovalsUL/ULC/USCG
USCG ClassificationType B:C, Size I
Effective Range10 ft - 12 ft (3.1m-3.7m)
Dimensions: Height × Width × Depth20-1/2 in (520mm)
8-1/4 in (210mm)
5-1/4 in (133mm)
Fire Suppression Capability: UL Panel Class A / Novice Operator Class B / Experienced Operator Class B8ft x 8ft (2.4 m x 2.4 m)
10ft² (0.93m²)
25ft² (2.32m²)

CA14-NM

Domestic Part No. 443479
International Part No.443580
Bracket Part No.
AgentFK-5-1-12
Agent Capacity14 lb (6.35kg)
Charged Weight19.16 lb (8.7kg)
Discharge Time11.0 sec
Agent Flow Rate1.45 lb/sec (0.66kg/sec)
Listings and ApprovalsUL/ULC
USCG Classification
Effective Range10 ft (3.1m)
Dimensions: Height × Width × Depth14-3/4 in (375mm)
9-1/4 in (234mm)
7-1/8 in (181mm)
Fire Suppression Capability: UL Panel Class A / Novice Operator Class B / Experienced Operator Class B8ft x 8ft (2.4 m x 2.4 m)
10ft² (0.93m²)
25ft² (2.32m²)

CA25

Domestic Part No. 443478
International Part No.439124
Bracket Part No.30937
AgentFK-5-1-12
Agent Capacity27.75 lb (12.6kg)
Charged Weight39.84 lb (18.07kg)
Discharge Time18 sec
Agent Flow Rate1.68 lb/sec (0.76kg/sec)
Listings and ApprovalsUL/ULC/USCG
USCG ClassificationType B:C, Size I
Effective Range14 ft - 16 ft (4.3m - 4.9m)
Dimensions: Height × Width × Depth23-7/8 in (606mm)
9-3/4 in (248mm)
7-3/8 in (187mm)
Fire Suppression Capability: UL Panel Class A / Novice Operator Class B / Experienced Operator Class B10ft x 10ft (3.1 m to 3.1 m)
10ft² (0.93m²)
25ft² (2.32m²)
Important: International model part numbers are used for shipments outside the United States in accordance with GHS labeling requirements. Hydrostatic testing is required once every 12 years for all models. Product specifications and availability may change; confirm all application and service requirements before ordering.

Model Abbreviations

  • CA = CLEANGUARD+ FK-5-1-12 clean-agent extinguisher
  • NM = Non-magnetic model
  • VB = Vehicle bracket configuration
  • USCG = United States Coast Guard approval
  • UL = Underwriters Laboratories
  • ULC = Underwriters Laboratories of Canada
Operator Classification: Underwriters Laboratories classifies a novice operator as a person with little or no experience operating a fire extinguisher.